Commands Listed in Alphabetical Order
Syntax
TRIGger:A:VID
eo:HDtv:FORMat
{HD1080P24|HD720P60|HD480P 60|HD1080I50|HD1080P25|
HD1080I60|HD1080PSF24}
TRIGger:A:VI
Deo:HDtv:FORMat?
Arguments
Table 2-42: Available HDTV formats
HDTV form a t Description
1080i50
1125 Lines (1080 active), 1920 x 1080 pixel,
interlaced, 60 fps
1080i60
1125 lines (1080 active), 1920 x 1080 pixel,
interlaced, 50 fps
1080p24
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 24 fps
1080p25
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 25 fps
1080sf24 1125 Lines (1080 active), 1920 x 1080 pixel,
progressive (sF), 24 fps
720p60
750 lines (720 active), 1280 x 720 pixel,
progressive, 60 fps
480p60
525 lines (480 active), 640 or 704 x 480
pixel, progressive, 60 fps
TRIGger:A:VIDeo:HOLDoff:FIELD
Sets or returns the video trigger holdoff in terms of video elds.
Conditions
This command requires a DPO4VID application module.
Group
Trigger
Syntax
TRIGger:A:VIDeo:HOLDoff:FI ELD <NR3>
TRIGger:A:VIDeo:HOLDoff:FI ELD?
Arguments
<NR3> argument is a real number from 0.0 to 8.5 in increments of 0.5. The
argument sets the number of elds that the oscilloscope waits before rearming
the video trigger.
Examples
TRIGGER:A:VIDEO:HOLDOFF:FI ELD? might return
:TRIGger:A:VIDeo:HOLdoff:F IELD 5 indicating that the oscilloscope is set
to wait 5 video elds before rearming the trigger.