Page view 322
Commands Listed in Alphabetical Order
Group
Power
Syntax
POWer:SWLoss:TOTal:POWER:M EAN?
Examples
POWER:SWLOSS:TOTAL:POWER:M EAN? might return
:POWER:SWLOSS:TOTAL:POWER: MEAN 1 indicating that the mean total power
switching loss calculation is set to 1 W.
POWer:SWLoss:TOTal:POWER:MIN? (Query Only)
Returns the minimum total power loss.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SWLoss:TOTal:POWER:M IN?
Examples
POWER:SWLOSS:TOTAL:POWER:M IN? might return
:POWER:SWLOSS:TOTAL:POWER: MIN 1 indicating that the minimum total
power switching loss calculation is set to 1 W.
POWer:SWLoss:VCEsat
Sets or returns VCESAT value for use in switching loss calculations when the
conduction calculation method is VCESAT.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SWLoss:VCEsat <NR3>
POWer:SWLoss:VCEsat?
Arguments
<NR3> is the VCEsat switching loss calculation.
MSO4000 and DPO4000 Series Programmer Manual 2-313