Tektronix DPO4000 User Manual Page 406

  • Download
  • Add to my manuals
  • Print
  • Page
    / 585
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 405
Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<1-4>:AUDio:DATa:QUALier
Sets or returns the trigger data qualier for the AU DIO bus.
Conditions
This command requires DPO4AUDIO application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<1-4>:AUDi o:DATa:QUALifier
{LESSThan|MOREThan|EQUal| UNEQual|LESSEQual|MOREEQual|INrange|OUTrange}
TRIGger:A:BUS:B<1-4>:AUDi o:DATa:QUALifier?
Arguments
LESSThan sets the Audio data qualier to less than.
MOREThan sets the Audio data qualier to greater than.
EQUal sets the Audio data qualier to equa l.
UNEQual sets the Audio data qualier to not equal.
LESSEQual sets the Audio d ata qualier to less than or equal.
MOREEQual sets the Audio data qualier to greater than or equal.
INrange sets the Audio data qualier to in range.
OUTrange sets the Audio data qualier to out of range.
TRIGger:A:BUS:B<1-4>:AUDio:DATa:VALue
Sets or returns the trigger data lower word for the AUDIO bus.
Conditions
This command requires DPO4AUDIO application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<1-4>:AUDi o:DATa:VALue <String>
TRIGger:A:BUS:B<1-4>:AUDi o:DATa:VALue?
Arguments
<String> species the trigger data lower word.
2-396 MSO4000 and DPO4000 Series Programmer Manual
Page view 405
1 2 ... 401 402 403 404 405 406 407 408 409 410 411 ... 584 585

Comments to this Manuals

No comments