User ManualTDS 500C, TDS 600B & TDS 700CDigitizing Oscilloscopes070-9869-00This document applies for firmware version 1.0and above.
Table of ContentsviTDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–87: Initial Help Screen 3–182. . . . . . . . . . . . . . . . . . . . . . . .
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–39To bring up the Display menu:Press DISPLAY ➞ Settings (main) ➞ Dis
Acquiring and Displaying Waveforms3–40TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–19: Display Menu — StyleNOTE. TDS 500C and TDS 700C model
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–411. TDS 600B: Press DISPLAY ➞ Readout Options (main).TDS 500C and T
Acquiring and Displaying Waveforms3–42TDS 500C, TDS 600B, & TDS 700C User ManualSometimes, especially when using the hardcopy feature, you may wan
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–43NOTE. Selecting either NTSC or PAL graticules automatically change
Acquiring and Displaying Waveforms3–44TDS 500C, TDS 600B, & TDS 700C User ManualSince selecting YT or XY affects only the display, the horizontal
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–45Figure 3–21: Display Menu — SettingTo choose a palette of 13 color
Acquiring and Displaying Waveforms3–46TDS 500C, TDS 600B, & TDS 700C User ManualNOTE. Use at higher room temperatures or with higher intensity dis
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–47ScrTxtFigure 3–22: Display Menu — Palette ColorsTo define math wav
Acquiring and Displaying Waveforms3–48TDS 500C, TDS 600B, & TDS 700C User Manual2. Select one of the four reference waveforms by pressing Ref in t
Table of ContentsTDS 500C, TDS 600B, & TDS 700C User ManualviiList of TablesTable 1–1: Key Features and differences of models 1–2. . . . . . . .
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–492. Select the object(s) you want to restore by pressing Reset Curr
Acquiring and Displaying Waveforms3–50TDS 500C, TDS 600B, & TDS 700C User ManualTo help you use zoom effectively, consider how it operates on wave
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–51To use Zoom, select a waveform, turn Zoom on, and magnify that wav
Acquiring and Displaying Waveforms3–52TDS 500C, TDS 600B, & TDS 700C User ManualOnly the selectedwaveform (the top one)changes size.Figure 3–25: Z
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–532. To scale or position the unmagnified waveform, press Selected G
Acquiring and Displaying Waveforms3–54TDS 500C, TDS 600B, & TDS 700C User ManualTo select Dual Zoom, press ZOOM ➞ Mode (main) ➞ Dual Zoom (side) t
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–55Selected GraticuleZoomed Waveform EdgesZoom BoxesUnzoomed Waveform
Acquiring and Displaying Waveforms3–56TDS 500C, TDS 600B, & TDS 700C User ManualInstaVu mode increases the waveform capture rate to up to 400,000
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–57Next AcquiredWaveformRecordNext AcquiredWaveformRecord1st Set of A
Acquiring and Displaying Waveforms3–58TDS 500C, TDS 600B, & TDS 700C User ManualTo change the InstaVu display style, do the following steps:1. Pre
Table of ContentsviiiTDS 500C, TDS 600B, & TDS 700C User Manual
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–59If you select any of these modes before or while InstaVu is on, th
Acquiring and Displaying Waveforms3–60TDS 500C, TDS 600B, & TDS 700C User ManualIf you are using the FastFrame mode, you can jump to the desired f
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–61If you shift the waveform right or left with the front-panel HORIZ
Acquiring and Displaying Waveforms3–62TDS 500C, TDS 600B, & TDS 700C User Manual
TDS 500C, TDS 600B, & TDS 700C User Manual3–63Triggering on WaveformsTo use the TDS Oscilloscope to measure or monitor waveforms, you need toknow
Triggering on Waveforms3–64TDS 500C, TDS 600B, & TDS 700C User ManualTriggered Waveform Untriggered WaveformsFigure 3–32: Triggered Versus Untrigg
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–65The digitizing oscilloscope provides three standard triggers for the main tri
Triggering on Waveforms3–66TDS 500C, TDS 600B, & TDS 700C User ManualAutomatic trigger mode (auto mode) enables the oscilloscope to acquire awavef
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–67Holdoff HoldoffIndicatesTrigger PointsTrigger LevelHoldoffAcquisitionInterval
Triggering on Waveforms3–68TDS 500C, TDS 600B, & TDS 700C User ManualThe slope control determines whether the oscilloscope finds the trigger point
TDS 500C, TDS 600B, & TDS 700C User ManualixGeneral Safety SummaryReview the following safety precautions to avoid injury and prevent damage tothi
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–69Trigger Status LightsFigure 3–35: TRIGGER Controls and Status LightsTo quickl
Triggering on Waveforms3–70TDS 500C, TDS 600B, & TDS 700C User ManualTo trigger on the next valid trigger event and then stop, press SHIFT FORCETR
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–71Trigger Readout. To quickly determine the settings of some key trigger param
Triggering on Waveforms3–72TDS 500C, TDS 600B, & TDS 700C User ManualTrigger Position Relative to theDisplay and Waveform RecordTrigger Point Indi
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–73Main Time BaseMain Time Base Time/DivMain TriggerSource = Ch 1Main Trigger Sl
Triggering on Waveforms3–74TDS 500C, TDS 600B, & TDS 700C User ManualTo select which source you want for the trigger:Press TRIGGER MENU ➞ Type (ma
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–75You can change the holdoff time and select the trigger mode using this menuit
Triggering on Waveforms3–76TDS 500C, TDS 600B, & TDS 700C User Manual2. Select the rising or falling edge from the side menu.Press the TRIGGER MEN
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–77 The Boolean logic function — select from AND, NAND, OR, and NOR The condit
Triggering on Waveforms3–78TDS 500C, TDS 600B, & TDS 700C User ManualFor state triggering, the oscilloscope waits until the end of trigger holdoff
General Safety SummaryxTDS 500C, TDS 600B, & TDS 700C User ManualDo Not Operate in Wet/Damp Conditions.Do Not Operate in an Explosive Atmosphere.K
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–79Setup/hold triggering uses the setup/hold violation zone to detect when data
Triggering on Waveforms3–80TDS 500C, TDS 600B, & TDS 700C User ManualClock SignalClock LevelTS = Setup TimeTH = Hold TimeSetup/Hold Violation Zone
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–81Trigger Class = StateCh 1, 2, 3 Inputs = High, Don’t Care, Don’t CareCh 4 Inp
Triggering on Waveforms3–82TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–42: Logic Trigger MenuTo Define Pattern Inputs. To set the logic st
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–83To Define the Logic. To choose the logic function you want applied to the inp
Triggering on Waveforms3–84TDS 500C, TDS 600B, & TDS 700C User ManualNote the position of the trigger indicator in Figure 3–43. Triggering occurs
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–85When you select the logic class State, the oscilloscope uses channel 4 as a c
Triggering on Waveforms3–86TDS 500C, TDS 600B, & TDS 700C User ManualTo Set Mode and Holdoff. Mode and holdoff can be set for all standard trigge
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–87Set the Data and Clock Levels. To set the transition levels that the clock an
Triggering on Waveforms3–88TDS 500C, TDS 600B, & TDS 700C User ManualData (Ch1) transition occurswithin 10 ns after the clockviolating hold time
TDS 500C, TDS 600B, & TDS 700C User ManualxiPrefaceThis is the User Manual for the TDS 500C, TDS 600B, & TDS 700C DigitizingOscilloscopes.The
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–89Triggering on PulsesThe TDS Oscilloscope can trigger on glitch or runt pulses
Triggering on Waveforms3–90TDS 500C, TDS 600B, & TDS 700C User ManualTrigger Class = RuntFigure 3–45: Pulse Trigger ReadoutsTable 3–7: Pulse trigg
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–91Table 3–7: Pulse trigger definitions (cont.)Name DefinitionSlew positive Trig
Triggering on Waveforms3–92TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–46: Main Trigger Menu — Glitch ClassSelect the Source. To specify wh
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–93Set to Accept or Reject Glitch. To specify whether to trigger on glitches or
Triggering on Waveforms3–94TDS 500C, TDS 600B, & TDS 700C User ManualSelect the Source. To specify which channel becomes the pulse trigger source:
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–95Selected trigger bar atupper threshold.Runt Pulse Crosses First ThresholdOnly
Triggering on Waveforms3–96TDS 500C, TDS 600B, & TDS 700C User ManualSet the Mode and Holdoff. Mode and holdoff can be set for all standard trigge
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–973. To set the range of pulse widths in units of time, press Upper Limit (side
Triggering on Waveforms3–98TDS 500C, TDS 600B, & TDS 700C User ManualNegative monitors the slew rate of the negative-going edges of pulses. The ed
PrefacexiiTDS 500C, TDS 600B, & TDS 700C User ManualDefault ModelThis manual documents the TDS 500C, TDS 600B, & TDS 700C DigitizingOscillosco
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–99Set to Trig When. The oscilloscope compares the pulse edge of the trigger sou
Triggering on Waveforms3–100TDS 500C, TDS 600B, & TDS 700C User ManualTrigger Bar at Upper ThresholdTrigger Bar at Lower ThresholdCursors Measure
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–101 The Trigger When side menu indicates the oscilloscope will trigger on puls
Triggering on Waveforms3–102TDS 500C, TDS 600B, & TDS 700C User ManualEither causes a trigger to occur if the signal stays lower or stays higher t
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–103Communications TriggeringThe TDS Oscilloscope can trigger on communication s
Triggering on Waveforms3–104TDS 500C, TDS 600B, & TDS 700C User ManualTable 3–8: Comm triggers (cont.)Standard Name Bit RateCode1STS-1 AMI 51.84
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–105Figure 3–49: Main Trigger Menu — Comm TypeTo select the standard and bit rat
Triggering on Waveforms3–106TDS 500C, TDS 600B, & TDS 700C User ManualTable 3–9: Communications pulse forms AMI CMI NRZIsolated +1 Plus One Eye Di
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–107There are two different ways to delay the acquisition of waveforms: delayed
Triggering on Waveforms3–108TDS 500C, TDS 600B, & TDS 700C User ManualNOTE. Due to hardware limitations, the delayed time base cannot be madetrigg
PrefaceTDS 500C, TDS 600B, & TDS 700C User Manualxiii Names also appear in the same case (initial capitals or all uppercase) in themanual as is u
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–109Time Delay(From Delay Trig Menu)Start Posttrigger Acquisition (Triggeron nth
Triggering on Waveforms3–110TDS 500C, TDS 600B, & TDS 700C User Manual4. If Type is set to Pulse, press Class (main) and change it to either Glitc
Triggering on WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–111Figure 3–53: Delayed Trigger Menu8. Press Source (main) ➞ Ch1, Ch2, Ch3, Ch4
Triggering on Waveforms3–112TDS 500C, TDS 600B, & TDS 700C User Manual11. Press Level (main) ➞ Level, Set to TTL, Set to ECL, or Set to 50% (side)
TDS 500C, TDS 600B, & TDS 700C User Manual3–113Measuring WaveformsTo make the best use of the TDS Oscilloscope when taking measurements, youneed t
Measuring Waveforms3–114TDS 500C, TDS 600B, & TDS 700C User ManualTaking Automated MeasurementsThe TDS Oscilloscope provides the feature Measure f
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–115Table 3–10: Measurement definitions (cont.)Name DefinitionCycle RMS Voltage meas
Measuring Waveforms3–116TDS 500C, TDS 600B, & TDS 700C User ManualTable 3–10: Measurement definitions (cont.)Name DefinitionPhase Timing measureme
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–117Measurement Readout AreaFigure 3–55: Measurement Readouts with StatisticsTo use
Measuring Waveforms3–118TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–56: Measure Menu Be careful when taking automatic measurements using E
PrefacexivTDS 500C, TDS 600B, & TDS 700C User Manual
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–119When gating is activated, vertical cursors are displayed. Use these cursors tode
Measuring Waveforms3–120TDS 500C, TDS 600B, & TDS 700C User ManualNOTE. Cursors are displayed relative to the selected waveform. If you are making
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–121Then choose whether the References are set in % relative to High (100%) and Low(
Measuring Waveforms3–122TDS 500C, TDS 600B, & TDS 700C User ManualThe delay measurement lets you measure from an edge on the selected waveformto a
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–1234. TDS 600B: Press MEASURE ➞ Select Measrmnt (main) ➞ Delay(side) ➞ Edges (main)
Measuring Waveforms3–124TDS 500C, TDS 600B, & TDS 700C User ManualTo use Snapshot, obtain a stable display of the waveform to be measured(pressing
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–125Consider the following rules when taking a snapshot: Be sure to display the wav
Measuring Waveforms3–126TDS 500C, TDS 600B, & TDS 700C User ManualTo display measurement statistics, obtain a stable display of the waveform to be
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–127There are three cursor types: horizontal bar, vertical bar, and paired (see Figu
Measuring Waveforms3–128TDS 500C, TDS 600B, & TDS 700C User ManualIn tracking mode, you normally move both cursors in tandem using the generalpurp
Getting Started
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–129Paired. The value after one D shows the voltage difference between the two Xs;th
Measuring Waveforms3–130TDS 500C, TDS 600B, & TDS 700C User ManualNon-selected Cursor(Dashed Vertical Bar)Cursor Readout (Paired)Selected Cursor(S
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–131 To adjust both cursors in tracking mode, use the general purpose knob tomove b
Measuring Waveforms3–132TDS 500C, TDS 600B, & TDS 700C User ManualTo find information on cursor units with video waveforms, see the TDS FamilyOpti
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–133To measure the time of a waveform, repeat the process just described, but countt
Measuring Waveforms3–134TDS 500C, TDS 600B, & TDS 700C User Manual Vertical displays a vertical histogram that shows how your vertical unitsvary
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–135The TDS Oscilloscope provides you with 10 histogram measurements.Table 3–11 list
Measuring Waveforms3–136TDS 500C, TDS 600B, & TDS 700C User Manual2. Press MEASURE ➞ Histogram (pop-up) ➞ Histogram Measrmnt (main).3. Select a me
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–137Figure 3–66: Mask menuNOTE. If you select Manual, some controls are automaticall
Measuring Waveforms3–138TDS 500C, TDS 600B, & TDS 700C User ManualTo enable the optical reference receiver (option 3C and 4C) required by someopti
Copyright Tektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its suppliers andare protected by United States
TDS 500C, TDS 600B, & TDS 700C User Manual1–1Product DescriptionThe Tektronix TDS Oscilloscope is a superb tool for acquiring, displaying, andmeas
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–1393. You create or edit a mask by moving a cross-hair cursor on the display andadd
Measuring Waveforms3–140TDS 500C, TDS 600B, & TDS 700C User ManualThese points formthe bottom of the maskThese points formthe top of the maskLeft-
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–141Table 3–12: Standard masks SONETSDHITU-T T1.102 Fibre channel Video Miscellaneou
Measuring Waveforms3–142TDS 500C, TDS 600B, & TDS 700C User ManualThe TDS Oscilloscope lets you compensate the internal signal path used toacquire
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–143Figure 3–68: Performing a Signal Path CompensationThe TDS Oscilloscopes allow yo
Measuring Waveforms3–144TDS 500C, TDS 600B, & TDS 700C User ManualRun a Probe Cal anytime you wish to ensure that the measurements you makeare mad
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–1452. Power on the digitizing oscilloscope and allow a 20 minute warm-up beforedoin
Measuring Waveforms3–146TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–69: Probe Cal Menu and Gain Compensation Display If gain compensation
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–14715. Note the compensation error amount. Skip to step 20.16. Disconnect the probe
Measuring Waveforms3–148TDS 500C, TDS 600B, & TDS 700C User ManualIf you execute a successful Probe Cal on an input channel, the oscilloscopestore
Product Description1–2TDS 500C, TDS 600B, & TDS 700C User ManualDifferences by ModelTable 1–1 lists some key TDS features and relates them to the
Measuring WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–149Figure 3–70: Re-use Probe Calibration Data MenuNOTE. If the Re-use Probe Calibra
Measuring Waveforms3–150TDS 500C, TDS 600B, & TDS 700C User ManualTable 3–13: Probe cal status be al1Uea iType probe connected2Probe Cal’d?1User a
TDS 500C, TDS 600B, & TDS 700C User Manual3–151Saving Waveforms and SetupsThe TDS Oscilloscope can save and recall the waveforms you measure and t
Saving Waveforms and Setups3–152TDS 500C, TDS 600B, & TDS 700C User ManualTo save the current setup of the oscilloscope:1. Press SAVE/RECALL SETUP
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–153NOTE. Upon power on, the oscilloscope creates the “wild card” file, mark
Saving Waveforms and Setups3–154TDS 500C, TDS 600B, & TDS 700C User ManualExecuting Tek Secure accomplishes the following tasks: Replaces all wav
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–155To save a waveform, do the following steps:1. Select the channel that ha
Saving Waveforms and Setups3–156TDS 500C, TDS 600B, & TDS 700C User ManualNOTE. Using this procedure to save an extended acquisition only saves th
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–157To select the format that the oscilloscope uses to save waveforms to a d
Saving Waveforms and Setups3–158TDS 500C, TDS 600B, & TDS 700C User ManualTo remove all stored reference waveforms and setups, use the feature cal
Product DescriptionTDS 500C, TDS 600B, & TDS 700C User Manual1–3Product SpecificationThe product specification is found in the technical reference
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–159TDS 500C or TDS 700C: Press SAVE/RECALL WAVEFORM ➞ Normal(pop-up) ➞ Reca
Saving Waveforms and Setups3–160TDS 500C, TDS 600B, & TDS 700C User ManualConsider the following operating characteristics when using autosave. A
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–1613. Press File Utilities in the main menu to bring up the File Utilities
Saving Waveforms and Setups3–162TDS 500C, TDS 600B, & TDS 700C User ManualTo delete a file or directory, turn the general purpose knob until it sc
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–163To copy a file or directory, turn the general purpose knob until it scro
Saving Waveforms and Setups3–164TDS 500C, TDS 600B, & TDS 700C User ManualTo turn on or off the file overwrite lock, toggle the side menu Overwrit
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–165The oscilloscope prints hardcopies of its display in many formats, which
Saving Waveforms and Setups3–166TDS 500C, TDS 600B, & TDS 700C User ManualSome formats, particularly Interleaf, EPS, TIFF, PCX, BMP, and HPGL, are
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–167Set Hardcopy Parameters. To specify the hardcopy format, layout, and typ
Saving Waveforms and Setups3–168TDS 500C, TDS 600B, & TDS 700C User ManualDate/Time Stamp the Hardcopy. You can display the current date and time
Product Description1–4TDS 500C, TDS 600B, & TDS 700C User Manual
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–169Set the Date and Time. You might need to set the date and time of the os
Saving Waveforms and Setups3–170TDS 500C, TDS 600B, & TDS 700C User ManualSome devices, such as the Tektronix HC100 Plotter, use the GPIB interfac
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–171Although not guaranteed, usually about 2.5 hardcopies can be spooled bef
Saving Waveforms and Setups3–172TDS 500C, TDS 600B, & TDS 700C User ManualTo make your hardcopies, use the procedures that follow.Connect to a Har
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–173NOTE. If you defined another name, use it instead of “DEV1”. Also, remem
Saving Waveforms and Setups3–174TDS 500C, TDS 600B, & TDS 700C User ManualCommunicating with Remote InstrumentsThe TDS Oscilloscope can connect in
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–175 Turn on at least two-thirds of the device loads present when you use y
Saving Waveforms and Setups3–176TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–82: Stacking GPIB ConnectorsTo set up remote communications, be
Saving Waveforms and SetupsTDS 500C, TDS 600B, & TDS 700C User Manual3–177Configure the GPIB Port. You must set two important GPIB parameters: mo
Saving Waveforms and Setups3–178TDS 500C, TDS 600B, & TDS 700C User ManualSee Printing a Hardcopy, on page 3–164.See the TDS Programmer Manual dis
TDS 500C, TDS 600B, & TDS 700C User Manual1–5Start UpBefore you use the TDS Oscilloscope, ensure that it is properly installed andpowered on.Prepa
TDS 500C, TDS 600B, & TDS 700C User Manual3–179Determining Status and Accessing HelpThe TDS Oscilloscope can display the status of its internal sy
Determining Status and Accessing Help3–180TDS 500C, TDS 600B, & TDS 700C User ManualFirmware VersionFigure 3–85: Status Menu — System
Determining Status and Accessing HelpTDS 500C, TDS 600B, & TDS 700C User Manual3–181Displaying the BannerTo display the banner (lists firmware ver
Determining Status and Accessing Help3–182TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–87: Initial Help ScreenWhen you press that button, th
TDS 500C, TDS 600B, & TDS 700C User Manual3–183Using Features for Advanced ApplicationsThe TDS Oscilloscope provides powerful features for testing
Using Features for Advanced Applications3–184TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–88: Comparing a Waveform to a Limit TemplateTo do
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–185Figure 3–89: Acquire Menu — Create Limit Test Template4. Pr
Using Features for Advanced Applications3–186TDS 500C, TDS 600B, & TDS 700C User ManualTo view the template you have created, press the MORE butto
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–1872. Ensure that the side button corresponding to the desired
Using Features for Advanced Applications3–188TDS 500C, TDS 600B, & TDS 700C User ManualYou can also compare more than one waveform against a singl
Start Up1–6TDS 500C, TDS 600B, & TDS 700C User ManualCAUTION. Using the P6243 or P6245 Active Probe to measure signals greaterthan ±40 volts may d
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–189To perform waveform math, use the More menu (Figure 3–90).
Using Features for Advanced Applications3–190TDS 500C, TDS 600B, & TDS 700C User ManualTo create a math waveform that requires two waveform source
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–191You can also select whether or not you wish to average a ce
Using Features for Advanced Applications3–192TDS 500C, TDS 600B, & TDS 700C User ManualThe FFT computes and displays the frequency content of a wa
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–193Normal Waveform of anImpulse ResponseFFT Waveform of theMag
Using Features for Advanced Applications3–194TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–93: Define FFT Waveform Menu7. Press Set FFT Vert
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–1958. Press Set FFT Window to (side) repeatedly to choose from
Using Features for Advanced Applications3–196TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–94: FFT Math Waveform in Math1Once you have displa
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–197Figure 3–95 shows the cursor measurement of a frequency mag
Using Features for Advanced Applications3–198TDS 500C, TDS 600B, & TDS 700C User Manual9. Read the frequency difference between the cursors from t
Start UpTDS 500C, TDS 600B, & TDS 700C User Manual1–7Power ConnectorPrincipal Power SwitchFuseFigure 1–1: Rear Panel Controls Used in Start Up5. C
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–199Waveform Record — the complete waveform record acquired fro
Using Features for Advanced Applications3–200TDS 500C, TDS 600B, & TDS 700C User ManualFFTs Transform Time Records to Frequency Records. The FFT t
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–201The following topics contain information to help you displa
Using Features for Advanced Applications3–202TDS 500C, TDS 600B, & TDS 700C User ManualTo speed up oscilloscope response when using long record le
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–203Whether Zoom is on or off, you can press Reset (main) ➞ Res
Using Features for Advanced Applications3–204TDS 500C, TDS 600B, & TDS 700C User Manual Filter the input to bandwidth limit it to frequencies bel
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–205To measure the phase relative to most source waveforms, you
Using Features for Advanced Applications3–206TDS 500C, TDS 600B, & TDS 700C User ManualYou specify the phase suppression level in dB with respect
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–207The FFT windowing acts like a bandpass filter between the F
Using Features for Advanced Applications3–208TDS 500C, TDS 600B, & TDS 700C User ManualIn step 8 (page 3–195) in To Create an FFT, the four window
Start Up1–8TDS 500C, TDS 600B, & TDS 700C User ManualON/STBY ButtonFigure 1–2: ON/STBY ButtonThe ON/STBY button controls power to most of the inst
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–209Leakage results when the time domain waveform delivered to
Using Features for Advanced Applications3–210TDS 500C, TDS 600B, & TDS 700C User ManualRectangular Window0 dB-20-40-50Hanning Window0 dB-20-40-60-
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–211The math waveform, derived from the sampled waveform, is co
Using Features for Advanced Applications3–212TDS 500C, TDS 600B, & TDS 700C User ManualDerivative Math WaveformSource WaveformFigure 3–101: Deriva
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–213Figure 3–102: Peak-Peak Amplitude Measurement of a Derivati
Using Features for Advanced Applications3–214TDS 500C, TDS 600B, & TDS 700C User ManualBecause of the method the oscilloscope uses to scale the so
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–215Whether zoom is on or off, you can press Reset (main) ➞ Res
Using Features for Advanced Applications3–216TDS 500C, TDS 600B, & TDS 700C User ManualTo obtain an integral math waveform, do the following steps
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–217Source WaveformIntegral Math WaveformFigure 3–103: Integral
Using Features for Advanced Applications3–218TDS 500C, TDS 600B, & TDS 700C User ManualSource WaveformIntegral Math WaveformFigure 3–104: H Bars C
Operating Basics
Using Features for Advanced ApplicationsTDS 500C, TDS 600B, & TDS 700C User Manual3–21913. Read the following values from the cursor readouts: Re
Using Features for Advanced Applications3–220TDS 500C, TDS 600B, & TDS 700C User ManualYou may be able to avoid saturating your integral waveform
Appendices
TDS 500C, TDS 600B, & TDS 700C User ManualA–1Appendix A: Options and AccessoriesThis appendix describes the various options as well as the standar
Appendix A: Options and AccessoriesA–2TDS 500C, TDS 600B, & TDS 700C User ManualTable A–1: Options (cont.)Option # DescriptionLabel1M130,000 recor
Appendix A: Options and AccessoriesTDS 500C, TDS 600B, & TDS 700C User ManualA–3Table A–1: Options (cont.)Option # DescriptionLabel2D Two probes D
Appendix A: Options and AccessoriesA–4TDS 500C, TDS 600B, & TDS 700C User ManualTable A–2: Standard Accessories (Cont.)Accessory Part NumberProbes
Appendix A: Options and AccessoriesTDS 500C, TDS 600B, & TDS 700C User ManualA–5The following optional accessory probes are recommended for use wi
Appendix A: Options and AccessoriesA–6TDS 500C, TDS 600B, & TDS 700C User Manual P5100 High Voltage Passive probe, 2.5 kV, DC to 250 MHz P5205 H
Appendix A: Options and AccessoriesTDS 500C, TDS 600B, & TDS 700C User ManualA–7The optional accessories listed in Table A–4 are Tektronix softwar
TDS 500C, TDS 600B, & TDS 700C User Manual2–1OverviewThis chapter describes the basic concepts of operating the TDS Oscilloscope.Understanding the
Appendix A: Options and AccessoriesA–8TDS 500C, TDS 600B, & TDS 700C User Manual
TDS 500C, TDS 600B, & TDS 700C User ManualB–1Appendix B: AlgorithmsThe TDS Oscilloscope can take 25 automatic measurements. By knowing how itmakes
Appendix B: AlgorithmsB–2TDS 500C, TDS 600B, & TDS 700C User ManualHistogram Method — attempts to find the highest density of points above andbelo
Appendix B: AlgorithmsTDS 500C, TDS 600B, & TDS 700C User ManualB–3LowRef — the waveform low reference level. Used in fall and rise timecalculatio
Appendix B: AlgorithmsB–4TDS 500C, TDS 600B, & TDS 700C User ManualMCross1, MCross2, and MCross3 — refer to the first, second, and third cro
Appendix B: AlgorithmsTDS 500C, TDS 600B, & TDS 700C User ManualB–5StartCycle — is the starting time for cycle measurements. It is a floating-poin
Appendix B: AlgorithmsB–6TDS 500C, TDS 600B, & TDS 700C User ManualMeasurement AlgorithmsThe automated measurements are defined and calculated as
Appendix B: AlgorithmsTDS 500C, TDS 600B, & TDS 700C User ManualB–7Timing measurement. The duration of a burst.1. Find on the waveform. Th
Appendix B: AlgorithmsB–8TDS 500C, TDS 600B, & TDS 700C User ManualTiming measurement. The amount of time between the and crossings
Appendix B: AlgorithmsTDS 500C, TDS 600B, & TDS 700C User ManualB–9HighHighRefLowRefLowTLFTHFFall TimeFigure B–2: Fall Time3. From , continue t
WARRANTYTektronix warrants that this product will be free from defects in materials and workmanship for a period of three (3) yearsfrom the date of sh
Overview2–2TDS 500C, TDS 600B, & TDS 700C User Manual
Appendix B: AlgorithmsB–10TDS 500C, TDS 600B, & TDS 700C User Manual0% (lowest) voltage reference value calculated. (See High, Low on page B–1.)Us
Appendix B: AlgorithmsTDS 500C, TDS 600B, & TDS 700C User ManualB–11Timing measurement. The ratio of the negative pulse width to the signal period
Appendix B: AlgorithmsB–12TDS 500C, TDS 600B, & TDS 700C User ManualTiming measurement. Time taken for one complete signal cycle. The reciprocalof
Appendix B: AlgorithmsTDS 500C, TDS 600B, & TDS 700C User ManualB–13Timing measurement. The ratio of the positive pulse width to the signal period
Appendix B: AlgorithmsB–14TDS 500C, TDS 600B, & TDS 700C User Manual3. From , continue the search, looking for a crossing of . Update
Appendix B: AlgorithmsTDS 500C, TDS 600B, & TDS 700C User ManualB–15The integration algorithm used by the oscilloscope is as follows:ŕBAW(t)dt is
Appendix B: AlgorithmsB–16TDS 500C, TDS 600B, & TDS 700C User ManualMeasurements on Envelope WaveformsTime measurements on envelope waveforms must
Appendix B: AlgorithmsTDS 500C, TDS 600B, & TDS 700C User ManualB–172. If the pair > , use the minima, else use maxima.If all pairs strad
Appendix B: AlgorithmsB–18TDS 500C, TDS 600B, & TDS 700C User Manual
TDS 500C, TDS 600B, & TDS 700C User ManualC–1Appendix C: Packaging for ShipmentIf you ship the TDS Oscilloscope, pack it in the original shipping
TDS 500C, TDS 600B, & TDS 700C User Manual2–3Operating Interface MapsThis section contains illustrations, or maps, of the display, the front and r
Appendix C: Packaging for ShipmentC–2TDS 500C, TDS 600B, & TDS 700C User Manual
TDS 500C, TDS 600B, & TDS 700C User ManualD–1Appendix D: Probe SelectionThe TDS Oscilloscope can use a variety of Tektronix probes for taking diff
Appendix E: Probe SelectionD–2TDS 500C, TDS 600B, & TDS 700C User ManualHowever, their 8 pF to 12 pF (over 60 pF for 1X) capacitive loading can di
Appendix E: Probe SelectionTDS 500C, TDS 600B, & TDS 700C User ManualD–3Figure D–1: Typical High Voltage ProbesActive Voltage ProbesActive voltage
Appendix E: Probe SelectionD–4TDS 500C, TDS 600B, & TDS 700C User ManualActive probes offer low input capacitance (1 to 2 pF typical) while mainta
Appendix E: Probe SelectionTDS 500C, TDS 600B, & TDS 700C User ManualD–5Use a current probe by clipping its jaws around the wire carrying the curr
Appendix E: Probe SelectionD–6TDS 500C, TDS 600B, & TDS 700C User ManualApplications include measuring the transient optical properties of lasers,
TDS 500C, TDS 600B, & TDS 700C User ManualE–1Appendix E: Inspection and CleaningInspect for dirt and damage on and clean the exterior of the TDS O
Appendix E: CleaningE–2TDS 500C, TDS 600B, & TDS 700C User ManualInspection. Inspect the outside of the oscilloscope for damage, wear, and missing
TDS 500C, TDS 600B, & TDS 700C User ManualF–1Appendix F: Programmer DiskThe TDS Family Programmer disk is a Microsoft Windows help file that cover
Operating Interface Maps2–4TDS 500C, TDS 600B, & TDS 700C User ManualFront Panel Map — Right SideHardcopy, page 3–164File System, page 3–160Autose
Appendix F: Programmer DiskF–2TDS 500C, TDS 600B, & TDS 700C User Manual
Glossary
TDS 500C, TDS 600B, & TDS 700C User ManualGlossary–1Glossary2 + 2 channel operationTwo-plus-two channel operation limits the simultaneous display
GlossaryGlossary–2TDS 500C, TDS 600B, & TDS 700C User ManualANDA logic (Boolean) function in which the output is true when and only whenall the in
GlossaryTDS 500C, TDS 600B, & TDS 700C User ManualGlossary–3Channel/probe deskewA relative time delay for each channel. This lets you align signal
GlossaryGlossary–4TDS 500C, TDS 600B, & TDS 700C User ManualDigitizingThe process of converting a continuous analog signal such as a waveform to a
GlossaryTDS 500C, TDS 600B, & TDS 700C User ManualGlossary–5General purpose knobThe large front-panel knob with an indentation. You can use it to
GlossaryGlossary–6TDS 500C, TDS 600B, & TDS 700C User ManualHigh The value used as 100% in automated measurements (whenever high ref,mid ref, and
GlossaryTDS 500C, TDS 600B, & TDS 700C User ManualGlossary–7InterleavingTDS 500B and TDS 700A Models Only: A method by which theseoscilloscopes at
GlossaryGlossary–8TDS 500C, TDS 600B, & TDS 700C User ManualMean Amplitude (voltage) measurement of the arithmetic mean over the entirewaveform.Mi
Operating Interface MapsTDS 500C, TDS 600B, & TDS 700C User Manual2–5Rear Panel MapRear Panel Connectors Security BracketGPIB Connector,page 3–174
GlossaryTDS 500C, TDS 600B, & TDS 700C User ManualGlossary–9OscilloscopeAn instrument for making a graph of two factors. These are typically volta
GlossaryGlossary–10TDS 500C, TDS 600B, & TDS 700C User ManualPositive widthA timing measurement of the distance (time) between two amplitudepoints
GlossaryTDS 500C, TDS 600B, & TDS 700C User ManualGlossary–11Rise timeThe time it takes for a leading edge of a pulse to rise from a LowRef value(
GlossaryGlossary–12TDS 500C, TDS 600B, & TDS 700C User ManualSide menuMenu that appears to the right of the display. These selections expand onmai
GlossaryTDS 500C, TDS 600B, & TDS 700C User ManualGlossary–13Vertical bar cursorsThe two vertical bars you position to measure the time parameter
GlossaryGlossary–14TDS 500C, TDS 600B, & TDS 700C User Manual
TDS 500C, TDS 600B, & TDS 700C User ManualIndex–1IndexNumbers1/seconds (Hz), Cursor menu, 3–1312 + 2 channel operation, xiv, 1–1, 1–2, Glossary–12
IndexIndex–2TDS 500C, TDS 600B, & TDS 700C User ManualAverage acquisition mode, 3–30, 3–61, Glossary–2Average mode, Acquire menu, 3–184Average, Ac
IndexTDS 500C, TDS 600B, & TDS 700C User ManualIndex–3Color, 3–44How to set, 3–44Color Deskjet, 3–165Color Matches Contents, Color menu, 3–47, 3–4
Operating Interface Maps2–6TDS 500C, TDS 600B, & TDS 700C User ManualDisplay MapThe value entered withthe general purposeknob or keypad.Channel le
IndexIndex–4TDS 500C, TDS 600B, & TDS 700C User ManualDData Source, Main Trigger menu, 3–86Date/TimeOn hardcopies, 3–168To set, 3–169DC coupling,
IndexTDS 500C, TDS 600B, & TDS 700C User ManualIndex–5YT, 3–43Display, Display menu, 3–39Display, Status menu, 3–179Dots, 3–39Dots style, Display
IndexIndex–6TDS 500C, TDS 600B, & TDS 700C User ManualFrame Length, Horizontal menu, 3–60Frame, Display menu, 3–42Frame, Horizontal menu, 3–60Freq
IndexTDS 500C, TDS 600B, & TDS 700C User ManualIndex–7Histograms, 3–133HistoMasks, Status menu, 3–179Hits in Box, 3–135Holdoff, trigger, 3–66, Glo
IndexIndex–8TDS 500C, TDS 600B, & TDS 700C User ManualLevel, Telecom Trigger menu, 3–106Level, Trigger, 3–68LF Rej, Main Trigger menu, 3–74Lightne
IndexTDS 500C, TDS 600B, & TDS 700C User ManualIndex–9Math1/2/3, More menu, 3–191Maximum, 3–115, Glossary–7Mean, 3–115, 3–135, Glossary–8Mean +– 1
IndexIndex–10TDS 500C, TDS 600B, & TDS 700C User ManualMeasure, 3–117, 3–124More, 3–158, 3–189, 3–193, 3–211Operation, 2–7Pop-up, 2–8, Glossary–9S
IndexTDS 500C, TDS 600B, & TDS 700C User ManualIndex–11PP6205 Active Probe, 1–5P6701A/B with calibration, A–2P6703A/B with calibration, A–2Packagi
IndexIndex–12TDS 500C, TDS 600B, & TDS 700C User ManualEdge trigger, 3–72General purpose knob, 2–6Logic trigger, 3–79Measurement, 3–116, 3–117Reco
IndexTDS 500C, TDS 600B, & TDS 700C User ManualIndex–13user status, 3–152Save/Recall WAVEFORM button, 3–155, 3–160Save/Recall Waveform menu, 3–155
Operating Interface MapsTDS 500C, TDS 600B, & TDS 700C User Manual2–7To Operate a Menu1 Press front-panel menu button. (Press SHIFT first if butt
IndexIndex–14TDS 500C, TDS 600B, & TDS 700C User ManualHisto/Masks, 3–179I/O, 3–179System, 3–179Trigger, 3–179Waveforms, 3–179StdDev, 3–135Stop Af
IndexTDS 500C, TDS 600B, & TDS 700C User ManualIndex–15Triggering on Waveforms, 3–63Triggering, Auto mode, Incompatible with InstaVu,3–58True for
IndexIndex–16TDS 500C, TDS 600B, & TDS 700C User ManualHow to set up, 3–96–3–112Width, Main Trigger menu, 3–92, 3–96Window, 3–206Blackman-Harris,
Operating Interface Maps2–8TDS 500C, TDS 600B, & TDS 700C User ManualTo Operate a Pop-Up MenuPress to display pop-up menus.Press it againto make s
TDS 500C, TDS 600B, & TDS 700C User Manual2–9TutorialThis section quickly makes you acquainted with some of the fundamentaloperations required to
Tutorial2–10TDS 500C, TDS 600B, & TDS 700C User ManualSignal GndFigure 2–1: Connecting a Probe for the Examples (P6245 shown)Do the following step
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–11SETUP ButtonFigure 2–2: SETUP Button LocationThe oscilloscope displays main menus along the
Tutorial2–12TDS 500C, TDS 600B, & TDS 700C User ManualNOTE. This manual uses the following notation to represent the sequence ofselections you mad
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–13 The trigger readout shows that the oscilloscope is triggering on channel 1(Ch1) on a risin
Tutorial2–14TDS 500C, TDS 600B, & TDS 700C User ManualThe display shows the probe compensation signal. It is a 1 kHz square wave ofapproximately 0
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–15When you first connect a signal to a channel and display it, the signal displayedmay not be
Tutorial2–16TDS 500C, TDS 600B, & TDS 700C User ManualAUTOSET ButtonFigure 2–8: AUTOSET Button LocationFigure 2–9 shows the display after pressing
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–17NOTE. If you are using a passive probe, such as the P6139A probe, the cornerson your display
Tutorial2–18TDS 500C, TDS 600B, & TDS 700C User ManualFigure 2–11: The Channel Buttons and LightsEach of the channel (CH) buttons has a light behi
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–19 There are two channel indicators at the left edge of the graticule. Rightnow, they overlap
Tutorial2–20TDS 500C, TDS 600B, & TDS 700C User ManualCh2 Reference IndicatorSide Menu TitleFigure 2–12: The Vertical Main Menu and Coupling Side
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–21Side Menu TitleFigure 2–13: The Menus After Changing ChannelsPressing the WAVEFORM OFF butto
TDS 500C, TDS 600B, & TDS 700C User ManualiTable of ContentsGeneral Safety Summary xi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tutorial2–22TDS 500C, TDS 600B, & TDS 700C User ManualExample 3: Taking Automated MeasurementsThe TDS Oscilloscope can measure many waveform param
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–23Observe that the frequency measurement appears within the right side of thegraticule area. T
Tutorial2–24TDS 500C, TDS 600B, & TDS 700C User ManualUse the Measure menu to remove waveforms you no longer want. To remove ameasurement individu
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–25To examine the current values, press Level Setup (main) ➞ High Ref (side).The General Purpos
Tutorial2–26TDS 500C, TDS 600B, & TDS 700C User ManualGeneral Purpose KnobSetting and ReadoutHighlightedMenu Itemwith BoxedReadoutValueGeneralPurp
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–271. Press Low Ref (side).2. On the numeric keypad, press the 2, the 0, and the ENTER () butto
Tutorial2–28TDS 500C, TDS 600B, & TDS 700C User ManualFigure 2–17: Snapshot of Channel 1Example 4: Saving SetupsThe TDS Oscilloscope can save its
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–29First, you need to create an instrument setup you want to save. Perform thefollowing steps t
Tutorial2–30TDS 500C, TDS 600B, & TDS 700C User ManualFigure 2–18: Save/Recall Setup Menu8. Press one of the To Setup side menu buttons to store t
TutorialTDS 500C, TDS 600B, & TDS 700C User Manual2–31To recall the setup, press SAVE/RECALL SETUP ➞ Recall Saved Set-up (main) ➞ Recall Setup (si
Table of ContentsiiTDS 500C, TDS 600B, & TDS 700C User ManualTriggering on Pulses 3–89. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tutorial2–32TDS 500C, TDS 600B, & TDS 700C User Manual
Reference
TDS 500C, TDS 600B, & TDS 700C User Manual3–1OverviewThis chapter describes in detail how to perform the operating tasks you must doto measure, te
Overview3–2TDS 500C, TDS 600B, & TDS 700C User ManualCoupling Waveforms to the Oscilloscope 3–5. . . . . . . . . . . . . . . . . . . . . . . . . S
OverviewTDS 500C, TDS 600B, & TDS 700C User Manual3–3Displaying Status 3–179. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview3–4TDS 500C, TDS 600B, & TDS 700C User Manual
TDS 500C, TDS 600B, & TDS 700C User Manual3–5Acquiring and Displaying WaveformsTo use the TDS Oscilloscope to measure or monitor waveforms, you ne
Acquiring and Displaying Waveforms3–6TDS 500C, TDS 600B, & TDS 700C User ManualThe remaining TDS 500C, TDS 600B, and TDS 700C oscilloscopes ship w
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–75. TDS 500C and 700C models only: Press SHIFT ACQUIRE MENU ➞Mode (m
Acquiring and Displaying Waveforms3–8TDS 500C, TDS 600B, & TDS 700C User Manual The oscilloscope switches to 50 W and disables AC coupling (and s
Table of ContentsTDS 500C, TDS 600B, & TDS 700C User ManualiiiList of FiguresFigure 1–1: Rear Panel Controls Used in Start Up 1–7. . . . . . . . .
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–9Do the following steps to automatically set up the oscilloscope:1.
Acquiring and Displaying Waveforms3–10TDS 500C, TDS 600B, & TDS 700C User ManualTable 3–1: Autoset defaults (Cont.)Control Changed by autoset toDi
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–11Do the following steps to reset the oscilloscope to its factory de
Acquiring and Displaying Waveforms3–12TDS 500C, TDS 600B, & TDS 700C User ManualChannel ReadoutChannel ReferenceIndicatorFigure 3–3: The Channel R
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–13Do the following steps to first display and then remove waveforms
Acquiring and Displaying Waveforms3–14TDS 500C, TDS 600B, & TDS 700C User ManualTo read about selecting reference waveforms, see Saving and Recall
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–15Original Position Positioned Vertically Positioned HorizontallyOri
Acquiring and Displaying Waveforms3–16TDS 500C, TDS 600B, & TDS 700C User Manual3. To make positioning faster, press the SHIFT button. When the li
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–17To select the coupling, bandwidth, and offset for the selected wav
Acquiring and Displaying Waveforms3–18TDS 500C, TDS 600B, & TDS 700C User ManualFine Scale. To make fine adjustments to the vertical scale, press
Table of ContentsivTDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–14: Equivalent-Time Sampling 3–27. . . . . . . . . . . . . . . . . . . . . .
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–19Check the Time Base readout at the lower right of the display to s
Acquiring and Displaying Waveforms3–20TDS 500C, TDS 600B, & TDS 700C User Manual2. If you want the POSITION knob to move faster, press the SHIFT b
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–21Trigger Position. The trigger point marks time zero in a waveform
Acquiring and Displaying Waveforms3–22TDS 500C, TDS 600B, & TDS 700C User Manual2. To fit an acquired waveform (or with Extended Acquisition On, a
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–23NOTE. To function properly, Extended acquisition mode forces some
Acquiring and Displaying Waveforms3–24TDS 500C, TDS 600B, & TDS 700C User Manual Wfm Len displays the length of the waveform record. The settings
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–25To perform tutorials that teach selecting, scaling, and positionin
Acquiring and Displaying Waveforms3–26TDS 500C, TDS 600B, & TDS 700C User ManualThe oscilloscope uses the samples it takes (see Figure 3–13) to cr
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–27A TDS 500C or TDS 700C model oscilloscope (the TDS 600B models use
Acquiring and Displaying Waveforms3–28TDS 500C, TDS 600B, & TDS 700C User ManualYour oscilloscope can interpolate between the samples it acquires.
Table of ContentsTDS 500C, TDS 600B, & TDS 700C User ManualvFigure 3–51: Delayed Triggerable 3–107. . . . . . . . . . . . . . . . . . . . . . . .
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–29A TDS 500C or TDS 700C Oscilloscope can interleave its channels to
Acquiring and Displaying Waveforms3–30TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–15 illustrates the different modes and lists the benefits
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–31Waveform Drawnon CRTSamples Acquired in FourAcquisition IntervalsD
Acquiring and Displaying Waveforms3–32TDS 500C, TDS 600B, & TDS 700C User ManualHi Res Mode. TDS 500C and 700C models only: Hi Res mode averages a
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–33To determine the acquisition sampling rate, the acquisition state
Acquiring and Displaying Waveforms3–34TDS 500C, TDS 600B, & TDS 700C User ManualNOTE. TDS 500C and 700C models only: Selecting Hi Res mode in the
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–35Check Table 3–4 below to determine the time base setting(s) at whi
Acquiring and Displaying Waveforms3–36TDS 500C, TDS 600B, & TDS 700C User ManualFigure 3–17: Acquire Menu — Stop After Press RUN/STOP button only
Acquiring and Displaying WaveformsTDS 500C, TDS 600B, & TDS 700C User Manual3–37NOTE. To quickly select Single Acquisition Sequence without displa
Acquiring and Displaying Waveforms3–38TDS 500C, TDS 600B, & TDS 700C User ManualMethods to Check and Eliminate. To quickly check for aliasing, slo
Comments to this Manuals